{"version":"1.0","provider_name":"Ohis","provider_url":"https:\/\/www.ohis.be\/en\/","title":"DC10 load measurement axis - Ohis","type":"rich","width":600,"height":338,"html":"<blockquote class=\"wp-embedded-content\" data-secret=\"L2PwESuQDp\"><a href=\"https:\/\/www.ohis.be\/en\/produit\/dc10-load-measurement-axis\/\">DC10 load measurement axis<\/a><\/blockquote><iframe sandbox=\"allow-scripts\" security=\"restricted\" src=\"https:\/\/www.ohis.be\/en\/produit\/dc10-load-measurement-axis\/embed\/#?secret=L2PwESuQDp\" width=\"600\" height=\"338\" title=\"&#8220;DC10 load measurement axis&#8221; &#8212; Ohis\" data-secret=\"L2PwESuQDp\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\" class=\"wp-embedded-content\"><\/iframe><script>\n\/*! This file is auto-generated *\/\n!function(d,l){\"use strict\";l.querySelector&&d.addEventListener&&\"undefined\"!=typeof URL&&(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&&!\/[^a-zA-Z0-9]\/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret=\"'+t.secret+'\"]'),o=l.querySelectorAll('blockquote[data-secret=\"'+t.secret+'\"]'),c=new RegExp(\"^https?:$\",\"i\"),i=0;i<o.length;i++)o[i].style.display=\"none\";for(i=0;i<a.length;i++)s=a[i],e.source===s.contentWindow&&(s.removeAttribute(\"style\"),\"height\"===t.message?(1e3<(r=parseInt(t.value,10))?r=1e3:~~r<200&&(r=200),s.height=r):\"link\"===t.message&&(r=new URL(s.getAttribute(\"src\")),n=new URL(t.value),c.test(n.protocol))&&n.host===r.host&&l.activeElement===s&&(d.top.location.href=t.value))}},d.addEventListener(\"message\",d.wp.receiveEmbedMessage,!1),l.addEventListener(\"DOMContentLoaded\",function(){for(var e,t,s=l.querySelectorAll(\"iframe.wp-embedded-content\"),r=0;r<s.length;r++)(t=(e=s[r]).getAttribute(\"data-secret\"))||(t=Math.random().toString(36).substring(2,12),e.src+=\"#?secret=\"+t,e.setAttribute(\"data-secret\",t)),e.contentWindow.postMessage({message:\"ready\",secret:t},\"*\")},!1)))}(window,document);\n\/\/# sourceURL=https:\/\/www.ohis.be\/wp-includes\/js\/wp-embed.min.js\n<\/script>\n","thumbnail_url":"https:\/\/www.ohis.be\/wp-content\/uploads\/2023\/01\/g_71590445.jpg","thumbnail_width":481,"thumbnail_height":783,"description":"DC10 load measurement axis  Sensor data Technical data of the sensor Measuring direction: Pressure Nominal load: 12.5 kN Limit load: 1.5 times nominal load Breaking load: > 3 times nominal load Accuracy: \u00b1 2 % full scale Reference temperature: 20 \u00b0C Nominal temperature range: -40 \u00b0C to +85 \u00b0C Operating temperature range: -40 \u00b0C to + 70 \u00b0C Temperature coefficient of signalling deviation < 0.2 % full scale O.\/10 K Temperature coefficient of zero point: < 0.21 % full scale \/ 10 K Degree of protection: IP 67  Other technical data Output signal: approx. 1 mV\/V Adjustment: 0 kN = 0,0 \u00b1 0,03 mV\/V ; +12,5 kN = 1,0 \u00b1 0,03 mV\/V Output resistance: Approx. 350 \u03a9 Supply voltage UB: \u00b1 10 V Insulation resistance: > 2 G\u03a9 Connector, 4-pole: Figure -X1 Pinout 1: UB+; 2: Sig+; 3: UB*; 4: Sig*"}